Line Sizing Chart for CellarPro Split Refrigeration Systems
Line Sizing Chart CellarPro Split Refrigeration Systems
| |
Suction Line Size by Length (ODS) |
|
Model |
Liquid Line Size (ODS) up to 100 Feet
|
Minimum Suction Line Insulation Thickness (in) |
Up to 25 Feet |
Between 25 and 50 Feet |
Between 50 and 100 Feet |
| Mini-Split 3000S |
1/4 |
1/2
|
1/2
|
1/2
|
1/2
|
| 4000S Split |
3/8 |
1/2
|
1/2
|
1/2
|
1/2
|
| 6000S Split / AH6500S |
3/8 |
1/2
|
1/2
|
5/8
|
5/8
|
| 8000S Split / AH8500S |
3/8 |
5/8
|
5/8
|
5/8
|
7/8
|
Notes:
(1) Line lengths are expressed in equivalent feet = actual run length + fitting allowances.
(2) Use only dehydrated refrigeration service tubing and refrigeration-grade fittings.
(3) Install refrigeration tubing in accordance with local codes and ASHRAE guidelines.
|
|
|
|